Skip to contents

NONMEM predicts A(n) / S<n> for the observation compartment, so a model that reports ng/mL off an mg / L system writes S2 = V2/1000. AUC at steady state in those units is dose * (V / S) / CL, not dose / CL, so without this factor AUC_SS is off by exactly the scaling applied in the model (1000 in that example).

Usage

get_dv_scale_factor(
  model = NULL,
  compartment = NULL,
  code = NULL,
  verbose = FALSE
)

Arguments

model

Pharmpy model object. NULL (or a model whose scaling cannot be read) gives 1.

compartment

observation compartment number. Inferred with get_obs_compartment() when NULL (the default). NONMEM models only.

code

nlmixr2 / rxode2 model code (character), read instead of model. The scaling an nlmixr-format model applies lives only in its rendered code — create_model(scale_observations = ) rewrites the prediction there as S<n> <- <vol>/<scale> — so the code is the only place it can be read back from, and it is also all a worker process has.

verbose

verbose output?

Value

single numeric multiplier.

Details

Returns 1 — i.e. plain dose / CL — whenever no scaling applies or none can be read off the model:

  • no S<n> is defined for the observation compartment, in which case NONMEM scales by 1 and the model predicts amounts rather than concentrations,

  • S<n> is the central volume itself (S2 = V2), the usual case,

  • S<n> is something other than the central volume times or divided by a constant, which is reported as a warning since AUC_SS is then not dose / CL in any simple way,